Plasma Surface Modification of 3Y-TZP at Low and Atmospheric Pressures with Different Treatment Times.


ABSTRACT: The efficiency of plasma surface modifications depends on the operating conditions. This study investigated the effect of chamber pressure and plasma exposure time on the surface properties of 3Y-TZP with N2/Ar gas. Plate-shaped zirconia specimens were randomly divided into two categories: vacuum plasma and atmospheric plasma. Each group was subdivided into five subgroups according to the treatment time: 1, 5, 10, 15, and 20 min. Following the plasma treatments, we characterized the surface properties, including wettability, chemical composition, crystal structure, surface morphology, and zeta potential. These were analyzed through various techniques, such as contact angle measurement, XPS, XRD, SEM, FIB, CLSM, and electrokinetic measurements. The atmospheric plasma treatments i

SUBMITTER: Kang SU 

PROVIDER: S-EPMC10144831 | biostudies-literature | 2023 Apr