ABSTRACT: Background
The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth.Aims
This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT).Methods
Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling