Clinical Evaluation of a Modified Light Transmission Short-Wavelength Filtering Intraocular Lens Compared to a Colorless Control.


ABSTRACT:

Introduction

The aim of this study was to evaluate the safety and efficacy of a violet-light filtering intraocular lens (IOL) compared to a colorless IOL control.

Methods

This was a prospective, bilateral, randomized, comparative, patient/evaluator-masked multi-center clinical trial at 12 sites in the USA. Patients underwent standard small-incision phacoemulsification cataract extraction. Visual acuity, contrast sensitivity, and color vision were tested 12 months postoperatively. Patient satisfaction and vision-related quality of life were evaluated based on directed patient responses obtained from a binocular subjective questionnaire.

Results

A total of 250 subjects were bilaterally implanted with the violet-light filtering TECNIS monofocal ZV9003 (n = 126) and color

SUBMITTER: Chang DH 

PROVIDER: S-EPMC10164208 | biostudies-literature | 2023 Jun