Unknown

Dataset Information

Treatment planning comparison of high-dose-rate brachytherapy vs. robotic and conventional stereotactic body radiotherapy for ultrahypofractionated treatment of prostate cancer.


ABSTRACT:

Background and purpose

Ultrahypofractionated radiation therapy is increasingly used in the treatment of prostate cancer. High-dose-rate brachytherapy (HDR-BT) and stereotactic body radiotherapy (SBRT) are representative methods of ultrahypofractionation. This study was performed to compare clinically applied treatment plans for patients who had been treated using HDR-BT vs. conventional or robotic SBRT.

Materials and methods

Calculated dose-volume indices between HDR-BT without a perirectal spacer (n = 20), robotic SBRT without a spacer (n = 40), and conventional (non-robotic) SBRT with a spacer (n = 40) were compared. Percentages against the prescription dose regarding the planning target volume (PTV), bladder, rectum, and urethra were statistically compared.

Results

SUBMITTER: Yoshioka Y 

PROVIDER: S-EPMC10183665 | biostudies-literature | 2023 Apr

REPOSITORIES: biostudies-literature