Ontology highlight
ABSTRACT: Purpose
Post-acute non-arteritic ischemic optic neuropathy (NAION) and glaucomatous optic neuropathy (GON) can be difficult to differentiate clinically. Our objective was to identify optical coherence tomography (OCT) parameters to help differentiate these optic neuropathies.Methods
We compared 12 eyes of 8 patients with NAION and 12 eyes of 12 patients with GON, matched for age and visual field mean deviation (MD). All patients underwent clinical assessment, automated perimetry (Humphrey Field Analyzer II; Carl Zeiss Meditec, Dublin, CA, USA), and OCT imaging (Spectralis OCT2; Heidelberg Engineering, Heidelberg, Germany) of the optic nerve head and macula. We derived the neuroretinal minimum rim width (MRW), peripapillary retinal nerve fibre layer (RNFL) thickness, central
SUBMITTER: Eadie BD
PROVIDER: S-EPMC10194940 | biostudies-literature | 2023
REPOSITORIES: biostudies-literature