Conduction system pacing is superior to biventricular pacing in patients with heart failure: Insights from the pooled clinical studies.
Ontology highlight
ABSTRACT: Background: The effects of conduction system pacing (CSP) compared with conventional biventricular pacing (BVP) on heart function in patients with heart failure remain elusive. Methods: PubMed, Embase, Cochrane's Library and Web of science databases were searched up to 1 October 2022 for pertinent controlled studies. Random or fixed-effect model were used to synthesize the clinical outcomes. Subgroup analysis was performed to screen the potential confounding factors. Results: Fifteen studies including 1,347 patients were enrolled. Compared with BVP, CSP was significantly associated with shortened QRS duration [WMD -22.51 ms; p = 0.000], improved left ventricular ejection fraction [WMD 5.53%; p = 0.000], improved NYHA grade [WMD -0.42; p = 0.000], h
SUBMITTER: Zhang J
PROVIDER: S-EPMC10196184 | biostudies-literature | 2023
REPOSITORIES: biostudies-literature
ACCESS DATA