Muscle Architecture and Subcutaneous Fat Measurements of Rectus Femoris and Vastus Lateralis at Optimal Length Aided by a Novel Ultrasound Transducer Attachment.
Ontology highlight
ABSTRACT: Purpose: This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. Methods: Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), p
SUBMITTER: Bulbrook BD
PROVIDER: S-EPMC10211386 | biostudies-literature | 2023