Unknown

Dataset Information

0

Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis.


ABSTRACT: This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the entire range of measured MFI-UF. However, the linearity was not reproducible, and different batches of dextran prepared under the same conditions produced very variable results. For polystyrene solutions, the MFI-UF linearity was verified at the higher range of MFI-UF (>10,000 s/L2), while the MFI-UF at the lower range (<5000 s/L2) appeared to be underestimated. Secondly, MFI-UF linearity was investigated using natural (surface) water under a wide range of testing conditions (at 20-200 L/m2·h using 5-100 kDa membranes). Strong MFI-UF linearity was obtained over the entire range of measured MFI-UF (up to 70,000 s/L2). Thus, the MFI-UF method was validated to measure different levels of particulate fouling in RO. However, future research focusing on MFI-UF calibration is still required through the selection, preparation, and testing of heterogeneous mixtures of standard particles.

SUBMITTER: Abunada M 

PROVIDER: S-EPMC10222867 | biostudies-literature | 2023 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis.

Abunada Mohanad M   Dhakal Nirajan N   Andyar William Z WZ   Li Yuke Y   Ajok Pamela P   Ghaffour Noreddine N   Schippers Jan C JC   Kennedy Maria D MD  

Membranes 20230522 5


This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the enti  ...[more]

Similar Datasets

| S-EPMC11775265 | biostudies-literature
| PRJNA629347 | ENA
| S-EPMC9143739 | biostudies-literature
2007-03-16 | GSE7266 | GEO
| S-EPMC4861925 | biostudies-other
| S-EPMC7823477 | biostudies-literature
| S-EPMC8232610 | biostudies-literature
2008-06-15 | E-GEOD-7266 | biostudies-arrayexpress
| S-EPMC10744386 | biostudies-literature
| S-EPMC3223915 | biostudies-literature