A Novel Method to Calculate Functional Pelvic Tilt Using a Standing Anteroposterior Pelvis Radiograph.


ABSTRACT:

Background

Functional patient-specific acetabular component positioning is important in total hip arthroplasty. We preoperatively evaluate the pelvic tilt (PT) on standing anteroposterior (AP) pelvis radiographs using a novel measurement and then recreate this intraoperatively using imaging. The purpose of this study was to determine if there is a linear correlation between this novel measurement and the actual PT.

Methods

A retrospective study of 200 patients was performed, measuring PT on standing lateral radiographs as the angle between the anterior superior iliac spines and the pubic symphysis. On the AP pelvis radiographs, the trans-teardrop (TT) line was drawn between the teardrops. The vertical distance between the TT line and the top of the pubic symphysis (TTPS) was

SUBMITTER: Frandsen JJ 

PROVIDER: S-EPMC10238463 | biostudies-literature | 2023 Jun

REPOSITORIES: biostudies-literature