Design, optimization, and evaluation of a wet electrostatic precipitator (ESP) for aerosol collection.
Ontology highlight
ABSTRACT: In this study, we developed, optimized, and evaluated in lab and field experiments a wet electrostatic precipitator (ESP) for the collection of ambient PM2.5 (particulate matter with aerodynamic diameter < 2.5 μm) into ultrapure water by applying an electrostatic charge to the particles. We operated the wet ESP at different flow rates and voltages to identify the optimal operating conditions. According to our experimental measurements, a flow rate of 125 lpm and an applied positive voltage of 11 kV resulted in a lower ozone generation of 133 ppb and a particle collection efficiency exceeding 80-90% in all size ranges. For the field tests, the wet ESP was compared with the versatile aerosol concentration enrichment system (VACES) connected to a BioSampler, a PTFE filter sampler,
SUBMITTER: Badami MM
PROVIDER: S-EPMC10249774 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA