Unknown

Dataset Information

0

Quantification of PEFC Catalyst Layer Saturation via In Silico, Ex Situ, and In Situ Small-Angle X-ray Scattering.


ABSTRACT: The complex nature of liquid water saturation of polymer electrolyte fuel cell (PEFC) catalyst layers (CLs) greatly affects the device performance. To investigate this problem, we present a method to quantify the presence of liquid water in a PEFC CL using small-angle X-ray scattering (SAXS). This method leverages the differences in electron densities between the solid catalyst matrix and the liquid water filled pores of the CL under both dry and wet conditions. This approach is validated using ex situ wetting experiments, which aid the study of the transient saturation of a CL in a flow cell configuration in situ. The azimuthally integrated scattering data are fitted using 3D morphology models of the CL under dry conditions. Different wetting scenarios are realized in silico, and the corresponding SAXS data are numerically simulated by a direct 3D Fourier transformation. The simulated SAXS profiles of the different wetting scenarios are used to interpret the measured SAXS data which allows the derivation of the most probable wetting mechanism within a flow cell electrode.

SUBMITTER: Aliyah K 

PROVIDER: S-EPMC10251350 | biostudies-literature | 2023 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantification of PEFC Catalyst Layer Saturation via In Silico, Ex Situ, and In Situ Small-Angle X-ray Scattering.

Aliyah Kinanti K   Prehal Christian C   Diercks Justus S JS   Diklić Nataša N   Xu Linfeng L   Ünsal Seçil S   Appel Christian C   Pauw Brian R BR   Smales Glen J GJ   Guizar-Sicairos Manuel M   Herranz Juan J   Gubler Lorenz L   Büchi Felix N FN   Eller Jens J  

ACS applied materials & interfaces 20230525 22


The complex nature of liquid water saturation of polymer electrolyte fuel cell (PEFC) catalyst layers (CLs) greatly affects the device performance. To investigate this problem, we present a method to quantify the presence of liquid water in a PEFC CL using small-angle X-ray scattering (SAXS). This method leverages the differences in electron densities between the solid catalyst matrix and the liquid water filled pores of the CL under both dry and wet conditions. This approach is validated using  ...[more]

Similar Datasets

| S-EPMC10201568 | biostudies-literature
| S-EPMC3192974 | biostudies-literature
| S-EPMC9835983 | biostudies-literature
| S-EPMC9515200 | biostudies-literature
| S-EPMC6497630 | biostudies-literature
| S-EPMC5627679 | biostudies-literature
| S-EPMC6408461 | biostudies-literature
| S-EPMC8153930 | biostudies-literature
| S-EPMC9092341 | biostudies-literature