Titanium Nitride Modified Fiber Optic Interferometer for Refractive Index Sensitivity Enhancement.


ABSTRACT: As one of the most well-established biocompatible transition metal nitrides, titanium nitride (TiN) has been widely applied for fiber waveguide coupling device applications. This study proposes a TiN-modified fiber optic interferometer. Benefiting from the unique properties of TiN, including ultrathin nanolayer, high refractive index, and broad-spectrum optical absorption, the refractive index (RI) response of the interferometer is greatly enhanced, which is desired all the time in the field of biosensing. The experimental results show that the deposited TiN nanoparticles (NPs) can enhance the evanescent field excitation and modulate the effective RI difference of the interferometer, which eventually results in the RI response enhancement. Besides, after incorporating the TiN with differen

SUBMITTER: Yi D 

PROVIDER: S-EPMC10256003 | biostudies-literature | 2023 Jun