Visible trephine-based foraminoplasty in PTED leads to asymmetrical stress changes and instability in the surgical and adjacent segments: a finite element analysis.
Ontology highlight
ABSTRACT: This study aimed to construct a multi-segment lumbar finite element model (FEM) of PTED surgery to analyze the changes in stress and ROM after visible trephine-based foraminoplasty. The CT scans of a 35-year-old healthy male were used to develop a multi-segment lumbar FEM with Mimic, Geomagic Studio, Hypermesh and MSC.Patran. Different foraminoplasty was performed on the model, and these were grouped into normal group (A), the ventral resection group (B), the apex resection group (C), the ventral + apex + isthmus resection group (D), and the SAP + isthmus + lateral recess resection group (E). A vertical load of 500N and a torque of 10N·M were applied to the upper surface of the L3 vertebral body to simulate the biomechanical characteristics under the motion of flexion, extension, lateral b
SUBMITTER: Wu W
PROVIDER: S-EPMC10265803 | biostudies-literature | 2023 Jun
REPOSITORIES: biostudies-literature
ACCESS DATA