ABSTRACT: Background
High-sensitivity cardiac troponin testing is a promising tool for cardiovascular risk prediction, but whether serial testing can dynamically predict risk is uncertain. We evaluated the trajectory of cardiac troponin I in the years prior to a cardiovascular event in the general population, and determine whether serial measurements could track risk within individuals.Methods
In the Whitehall II cohort, high-sensitivity cardiac troponin I concentrations were measured on three occasions over a 15-year period. Time trajectories of troponin were constructed in those who died from cardiovascular disease compared to those who survived or died from other causes during follow up and these were externally validated in the HUNT Study. A joint model that adjusts for cardiovas
SUBMITTER: Kimenai DM
PROVIDER: S-EPMC10280894 | biostudies-literature | 2023 Jun