Innovative reference materials for method validation in microplastic analysis including interlaboratory comparison exercises.
Ontology highlight
ABSTRACT: Reference materials (RMs) are vital tools in the validation of methods used to detect environmental pollutants. Microplastics, a relatively new environmental pollutant, require a variety of complex approaches to address their presence in environmental samples. Both interlaboratory comparison (ILC) studies and RMs are essential to support the validation of methods used in microplastic analysis. Presented here are results of quality assurance and quality control (QA/QC) performed on two types of candidate microplastic RMs: dissolvable gelatin capsules and soda tablets. These RMs have been used to support numerous international ILC studies in recent years (2019-2022). Dissolvable capsules containing polyethylene terephthalate (PET), polyvinyl chloride (PVC), polyethylene (PE), and polystyrene
SUBMITTER: Martinez-Frances E
PROVIDER: S-EPMC10285000 | biostudies-literature | 2023 Jun
REPOSITORIES: biostudies-literature