Unknown

Dataset Information

Electrically evoked electroretinograms and pupil responses in Argus II retinal implant wearers.


ABSTRACT:

Purpose

We have recorded the electrically evoked electroretinogram (eERG) and flash ERG in Argus II retinal prosthesis wearers with end-stage retinitis pigmentosa to estimate response properties of the degenerated inner retina to local electrical stimulation. In addition, we have recorded pupil diameters during electrical stimulation.

Methods

Raw corneal eERGs were recorded at multiple stimulus levels in three subjects. eERG signals were heavily contaminated with various artifacts, including switching artifacts generated by the implant electronics, stimulus, blink, and eye-movement artifacts. Pupil responses were recorded in one subject using a pupil tracker.

Results

eERGs were decontaminated by a variety of techniques, including wavelet transformation and response av

SUBMITTER: Stronks HC 

PROVIDER: S-EPMC10290545 | biostudies-literature | 2016 Feb

REPOSITORIES: biostudies-literature