Experimental and numerical data of thermal response tests executed in groups of energy piles connected in series.
Ontology highlight
ABSTRACT: The use of energy piles as heat exchangers for Ground Source Heat Pump (GSHP) systems, providing heating and cooling, is a well researched application worldwide [1]. However, a broader implementation in practice still faces resistance, mainly because of the lack of accessible, easy to implement design methods and uncertainty regarding the thermo-mechanical effects. These issues need to be addressed to close the gap between research and practice. This work presents data of a full-scale thermal response test (TRT) undertaken in a group of eight energy screw piles connected in series, that are part of an operational GSHP system of a building located in Melbourne, Australia. The temperature was measured in the inlet and outlet of the pipe circuit (circulating water temperature) and at the bott
SUBMITTER: Bandeira Neto L
PROVIDER: S-EPMC10293976 | biostudies-literature | 2023 Jun
REPOSITORIES: biostudies-literature