Unknown

Dataset Information

0

The "safe-line" technique as theoretical additional attempt to mitigate spinal cord ischemia after urgent complete endovascular exclusion of a thoracoabdominal aortic aneurysm.


ABSTRACT: We describe the feasibility of a technique for temporary aneurysm sac reperfusion after endovascular single-stage thoracoabdominal aortic aneurysm exclusion, to be used in the case of postoperative spinal cord ischemia. Two cases were treated for impending rupture of a thoracoabdominal aortic aneurysm. Before completion of sac exclusion, a supplementary buddy wire (V-18 control guidewire; Boston Scientific) was advanced in parallel fashion from the left percutaneous femoral access into the aneurysmal sac on the posterior aspect of the endograft. Distal aneurysm exclusion was completed using the main superstiff guidewire, and the femoral access was closed with a percutaneous closure device (ProGlide; Abbott) in standard fashion, leaving in place the sole V-18 guidewire, draped in sterile fashion. In the case of spinal cord ischemia, the "safe-line" can be rapidly used for spinal reperfusion after trans-sealing exchange with a 6F, 65-cm-long Destination sheath (Terumo) connected to a 6F introducer on the contralateral femoral artery.

SUBMITTER: Piazza M 

PROVIDER: S-EPMC10319321 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

The "safe-line" technique as theoretical additional attempt to mitigate spinal cord ischemia after urgent complete endovascular exclusion of a thoracoabdominal aortic aneurysm.

Piazza Michele M   Squizzato Francesco F   Bilato Marco James MJ   Forcella Edoardo E   Grego Franco F   Antonello Michele M  

Journal of vascular surgery cases and innovative techniques 20230516 3


We describe the feasibility of a technique for temporary aneurysm sac reperfusion after endovascular single-stage thoracoabdominal aortic aneurysm exclusion, to be used in the case of postoperative spinal cord ischemia. Two cases were treated for impending rupture of a thoracoabdominal aortic aneurysm. Before completion of sac exclusion, a supplementary buddy wire (V-18 control guidewire; Boston Scientific) was advanced in parallel fashion from the left percutaneous femoral access into the aneur  ...[more]

Similar Datasets

| S-EPMC10407483 | biostudies-literature
| S-EPMC7378364 | biostudies-literature
| S-EPMC3276362 | biostudies-literature
| S-EPMC7044192 | biostudies-literature
| S-EPMC10964665 | biostudies-literature
| S-EPMC10561345 | biostudies-literature
| S-EPMC9486727 | biostudies-literature
| S-EPMC9974809 | biostudies-literature