Live-view 4D GRASP MRI: A framework for robust real-time respiratory motion tracking with a sub-second imaging latency.


ABSTRACT:

Purpose

To propose a framework called live-view golden-angle radial sparse parallel (GRASP) MRI for low-latency and high-fidelity real-time volumetric MRI.

Methods

Live-view GRASP MRI has two stages. The first one is called an off-view stage and the second one is called a live-view stage. In the off-view stage, 3D k-space data and 2D navigators are acquired alternatively using a new navi-stack-of-stars sampling scheme. A 4D motion database is then generated that contains time-resolved MR images at a sub-second temporal resolution, and each image is linked to a 2D navigator. In the live-view stage, only 2D navigators are acquired. At each time point, a live-view 2D navigator is matched to all the off-view 2D navigators. A 3D image that is linked to the best-matched off-view 2

SUBMITTER: Feng L 

PROVIDER: S-EPMC10330383 | biostudies-literature | 2023 Sep