A comparison of bioelectrical impedance analysis and air displacement plethysmography to assess body composition in children.


ABSTRACT:

Background

Accurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for the assessment of BC and is widely used in children. However, studies of the effectiveness of BIA are few and present different results, especially in pediatric populations. The aim of this study was to evaluate the agreement between BIA and ADP for estimating BC.

Methods

The BC of 981 Chinese children (3-5 years) was measured using the BIA device (SeeHigher BAS-H, China) and ADP (BOD POD).

Results

Our results showed that BIA underestimated fat mass (FM) and overestimated fat-free mass (FFM) in normal weight children

SUBMITTER: Chen F 