ABSTRACT: Background and purpose
Metallic hip prostheses cause substantial artefacts in both computed tomography (CT) and magnetic resonance (MR) images used in radiotherapy treatment planning (RTP) for prostate cancer patients. The aim of this study was to evaluate the dose calculation accuracy of a synthetic CT (sCT) generation workflow and the improvement in implant visibility using metal artefact reduction sequences.Materials and methods
The study included 23 patients with prostate cancer who had hip prostheses, of which 10 patients had bilateral hip implants. An in-house protocol was applied to create sCT images for dose calculation comparison. The study compared prostheses volumes and resulting avoidance sectors against planning target volume (PTV) dose uniformity and organs at