Research on the air supply adjustment technology of breath-following powered air-purifying respirators.
Ontology highlight
ABSTRACT: In the hope of reducing the air supply flow of the powered air-purifying respirator (PAPR) and extending the service life of the filter, a breath-following powered air-purifying respirator (BF-PAPR) that can dynamically adjust the air supply flow according to the breathing flow is proposed. The BF-PAPR changes the air supply flow by adjusting the speed of the variable-frequency centrifugal fan according to the air velocity at the half mask outlet (vhm) monitored by the modular wind speed transmitter. In the study, the air supply flow adjustment model of the BF-PAPR is developed. It is found that the filtration resistance barely influences vhm. In addition, under the same mean inhalation flow, the minimum outlet air velocity increases first and then decreases with the
SUBMITTER: Teng G
PROVIDER: S-EPMC10374598 | biostudies-literature | 2023 Jul
REPOSITORIES: biostudies-literature
ACCESS DATA