Unknown

Dataset Information

0

Reagent Effects on the Activated Partial Thromboplastin Time Clot Waveform Analysis: A Multi-Centre Study.


ABSTRACT: (1) Background: The activated partial thromboplastin time (APTT)- based clot waveform analysis (CWA) quantitatively extends information obtained from the APTT waveform through its derivatives. However, pre-analytical variables including reagent effects on the CWA parameters are poorly understood and must be standardized as a potential diagnostic assay. (2) Methods: CWA was first analysed with patient samples to understand reagent lot variation in three common APTT reagents: Pathromtin SL, Actin FS, and Actin FSL. A total of 1055 healthy volunteers were also recruited from seven institutions across the Asia-Pacific region and CWA data were collected with the Sysmex CS analysers. (3) Results: CWA parameters varied less than 10% between lots and the linear mixed model analysis showed few site-specific effects within the same reagent group. However, the CWA parameters were significantly different amongst all reagent groups and thus reagent-specific 95% reference intervals could be calculated using the nonparametric method. Post-hoc analysis showed some degree of influence by age and gender with weak correlation to the CWA (r < 0.3). (4) Conclusions: Reagent type significantly affects APTT-based CWA with minimal inter-laboratory variations with the same coagulometer series that allow for data pooling across laboratories with more evidence required for age- and gender-partitioning.

SUBMITTER: Wong WH 

PROVIDER: S-EPMC10377778 | biostudies-literature | 2023 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reagent Effects on the Activated Partial Thromboplastin Time Clot Waveform Analysis: A Multi-Centre Study.

Wong Wan Hui WH   Tan Chuen Wen CW   Abdul Khalid Nabeelah Binti NB   Dalimoenthe Nadjwa Zamalek NZ   Yip Christina C   Tantanate Chaicharoen C   Lim Rodelio D RD   Kim Ji Hyun JH   Ng Heng Joo HJ  

Diagnostics (Basel, Switzerland) 20230722 14


(1) Background: The activated partial thromboplastin time (APTT)- based clot waveform analysis (CWA) quantitatively extends information obtained from the APTT waveform through its derivatives. However, pre-analytical variables including reagent effects on the CWA parameters are poorly understood and must be standardized as a potential diagnostic assay. (2) Methods: CWA was first analysed with patient samples to understand reagent lot variation in three common APTT reagents: Pathromtin SL, Actin  ...[more]

Similar Datasets

| S-EPMC11649911 | biostudies-literature
| S-EPMC9435534 | biostudies-literature
| S-EPMC9509521 | biostudies-literature
| S-EPMC9602091 | biostudies-literature
| S-EPMC9371343 | biostudies-literature
| S-EPMC4532488 | biostudies-literature
| S-EPMC8766202 | biostudies-literature
| S-EPMC8159641 | biostudies-literature
| S-EPMC3682876 | biostudies-literature
| S-EPMC2850435 | biostudies-literature