Reduction of aerosol dissemination in a dental area generated by high-speed and scaler ultrasonic devices employing the "Prime Protector".


ABSTRACT: The use of an external dome aerosol containment device (Prime Protector) is proposed to reduce the spread of particles within the dental office. Hence, the aim of our study was to compare the spread of bioaerosols generated by a High-speed Handpiece (HH) and an Ultrasonic Prophylaxis Device (UPD), with and without the Prime Protector dome (PP) by counting Colony Forming Units (CFU) of Lactobacillus casei Shirota, at different distances on the x and y axis. The PP was located considering the parallelism between the base of the dome and the frontal plane of the simulator, aligning the center of the mouth with the center of the dome. The PP dome measurements are 560.0mm x 255.0mm x 5mm. Petri dishes were placed at 0.5 m, 1 m and 1.5 m respectively. Aerosol generation in the laboratory environ