The minimum required overlap length for tendon transfer A biomechanical study on human tendons.


ABSTRACT: In tendon transfer surgeries sufficient stability of the tenorrhaphy is essential. In addition to the choice of a suitable technique, adequate overlap of donor and recipient tendons must be ensured. The aim of this study was to investigate the tensile strength with regard to tendon overlap of a recently published tenorrhaphy, termed Woven-Fridén (WF) tenorrhaphy, which displayed higher tensile strength and lower bulk when compared to the established Pulvertaft technique. For this purpose, WF tenorrhaphies with 1.5 cm, 2 cm, and 3 cm tendon overlap were performed and subsequently tested for different biomechanical properties by tensile testing. Among others, the parameters of ultimate load and stiffness were collected. Native tendons served as controls. A formula was derived to quantify the relation between tendon overlap and ultimate load. We observed that sufficient tensile strength (mean ultimate load of 217 N) is already given with a 2 cm tendon overlap. In addition, with more than 3 cm overlap length only little additional tensile strength is to be expected as the calculated ultimate load of 4 cm overlap (397 N) is approaching the plateau of the maximal ultimate load of 435 N (native tendons).

SUBMITTER: Wachtel N 

PROVIDER: S-EPMC10403071 | biostudies-literature | 2023

REPOSITORIES: biostudies-literature

altmetric image

Publications

The minimum required overlap length for tendon transfer A biomechanical study on human tendons.

Wachtel Nikolaus N   Englbrecht Marc A MA   Micheler Carina C   Lang Jan J JJ   Burgkart Rainer R   Giunta Riccardo E RE   Wilhelm Christina J CJ  

PloS one 20230804 8


In tendon transfer surgeries sufficient stability of the tenorrhaphy is essential. In addition to the choice of a suitable technique, adequate overlap of donor and recipient tendons must be ensured. The aim of this study was to investigate the tensile strength with regard to tendon overlap of a recently published tenorrhaphy, termed Woven-Fridén (WF) tenorrhaphy, which displayed higher tensile strength and lower bulk when compared to the established Pulvertaft technique. For this purpose, WF ten  ...[more]

Similar Datasets

| S-EPMC7217614 | biostudies-literature
| S-EPMC3621034 | biostudies-literature
| S-EPMC2269010 | biostudies-other
| S-EPMC5666880 | biostudies-literature
| S-EPMC5007538 | biostudies-literature
| S-EPMC8512990 | biostudies-literature
| S-EPMC11571790 | biostudies-literature
| S-EPMC9514661 | biostudies-literature
| S-EPMC7049442 | biostudies-literature
| S-EPMC9850051 | biostudies-literature