Efficacy of novel SARS-CoV-2 rapid antigen tests in the era of omicron outbreak.
Ontology highlight
ABSTRACT: Following the outbreak of Omicron and its subvariants, many of the currently available rapid Ag tests (RATs) showed a decrease in clinical performance. In this study, we evaluated the clinical sensitivity of the SARS-CoV-2 Rapid Antigen Test 2.0 for nasopharyngeal swabs and SARS-CoV-2 Rapid Antigen Test 2.0 Nasal for nasal swabs in 56 symptomatic individuals by comparing the results between RATs, RT-PCR, Omicron RT-PCR, and whole-genome sequencing (WGS). Furthermore, sequences of the Omicron subvariants' spike proteins were subjected to phylogenetic analysis. Both novel RATs demonstrated a high sensitivity of up to 92.86%, (95% CI 82.71%- 98.02%), 94.23%, (95% CI 83.07%- 98.49%), and 97.95% (95% CI 87.76%- 99.89%) compared to the RT-PCR, Omicron RT-PCR, and WGS, respectively. The clinical
SUBMITTER: Widyasari K
PROVIDER: S-EPMC10414561 | biostudies-literature | 2023
REPOSITORIES: biostudies-literature
ACCESS DATA