Effect of the arrangement of cavitation generation unit on the performance of an advanced rotational hydrodynamic cavitation reactor.
Ontology highlight
ABSTRACT: Hydrodynamic cavitation (HC) is widely considered a promising process intensification technology. The novel advanced rotational hydrodynamic cavitation reactors (ARHCRs), with considerably higher performance compared with traditional devices, have gained increasing attention of academic and industrial communities. The cavitation generation unit (CGU), located on the rotor and/or stator of an ARHCR, is utilized to generate cavitation and consequently, its geometrical structure is vital for the performance. The present work studied, for the first time, the effect of the arrangement of CGU on the performance of a representative ARHCR by employing computational fluid dynamics based on the "simplified flow field" strategy. The effect of CGU arrangement, which was neglected in the past, was eval
SUBMITTER: Sun X
PROVIDER: S-EPMC10432248 | biostudies-literature | 2023 Jul
REPOSITORIES: biostudies-literature