Unknown

Dataset Information

0

Kinetics of cardiac troponin and other biomarkers in patients with ST elevation myocardial infarction.


ABSTRACT:

Objective

To examine changes in concentration, time-to-peak and the ensuing half-life of cardiac biomarkers in patients with myocardial infarction.

Methods

Blood sampling was performed every third hour within 24 h after percutaneous coronary intervention (PCI) on a cohort of patients with ST elevation myocardial infarction. Cardiac troponin (cTn) was measured by the Dimension Vista, Vitros, Atellica, and Alinity high-sensitivity (hs) cTnI assays, and the Elecsys hs-cTnT assay. Further, creatine kinase (CK), myoglobin, creatine kinase MB (CKMB) and other biomarkers were analyzed.

Results

A total of 36 patients completed blood sampling (median age 60 years, IQR 56.4-66.5 years; seven women, 19.4%). Hs-cTnI measured by the Vitros assay was the first hs-cTn to peak at 9.1 h (95%-CI 6.2-10.1) after PCI and 11.7 h (95%-CI 10.4-14.8) after symptoms onset. There were no notable differences between hs-cTn assays in regard to time-to-peak. Also, Vitros hs-cTnI reached the highest median ratio of concentration to upper reference level of nearly 2,000. The median half-life from peak concentration ranged from 7.6 h for myoglobin (CI 6.8-8.6) to 17.8 h for CK (CI 6.8-8.6). For hs-cTn assays the median T½ ranged from 12.4 h for the Vista hs-cTnI assay (95%-CI 11.0-14.1 h) to 17.3 h for the Elecsys hs-cTnT (95%-CI 14.9-20.8 h).

Conclusions

This study updates knowledge on the kinetics of cardiac biomarkers in current clinical use. There was no notable difference in trajectories, time-to-peak or half-life between hs-cTn assays.

SUBMITTER: Henrik Kristensen J 

PROVIDER: S-EPMC10432699 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objective</h4>To examine changes in concentration, time-to-peak and the ensuing half-life of cardiac biomarkers in patients with myocardial infarction.<h4>Methods</h4>Blood sampling was performed every third hour within 24 h after percutaneous coronary intervention (PCI) on a cohort of patients with ST elevation myocardial infarction. Cardiac troponin (cTn) was measured by the Dimension Vista, Vitros, Atellica, and Alinity high-sensitivity (hs) cTnI assays, and the Elecsys hs-cTnT assay. Fur  ...[more]

Similar Datasets

| S-EPMC8929978 | biostudies-literature
| S-EPMC5922709 | biostudies-other
| S-EPMC9168824 | biostudies-literature
| S-EPMC8360674 | biostudies-literature
| S-EPMC9344428 | biostudies-literature
| S-EPMC6536392 | biostudies-literature
| S-EPMC10858964 | biostudies-literature
| S-EPMC5501718 | biostudies-other
2015-05-23 | E-GEOD-61145 | biostudies-arrayexpress
| S-EPMC8127550 | biostudies-literature