Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients.


ABSTRACT: For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.

SUBMITTER: Dortez S 

PROVIDER: S-EPMC10448438 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients.

Dortez Silvia S   DeGregorio-Rocasolano Núria N   Millán Mònica M   Gasull Teresa T   Crevillen Agustín G AG   Escarpa Alberto A  

Analytical chemistry 20230724 33


For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was m  ...[more]

Similar Datasets

| S-EPMC3852662 | biostudies-literature
| S-EPMC5026239 | biostudies-literature
| S-EPMC5701284 | biostudies-literature
| S-EPMC10649804 | biostudies-literature
| S-EPMC7450514 | biostudies-literature
| S-EPMC6030327 | biostudies-literature
| S-EPMC7071557 | biostudies-literature
| S-EPMC6055620 | biostudies-literature
| S-EPMC10499984 | biostudies-literature
| S-EPMC9145873 | biostudies-literature