Validity and reliability of an electromyography-based upper limb assessment quantifying selective voluntary motor control in children with upper motor neuron lesions.
Ontology highlight
ABSTRACT: Current clinical assessments evaluating selective voluntary motor control are measured on an ordinal scale. We combined the Selective Control of the Upper Extremity Scale (SCUES) with surface electromyography to develop a more objective and interval-scaled assessment of selective voluntary motor control. The resulting Similarity Index (SI) quantifies the similarity of muscle activation patterns. We aimed to evaluate the validity and reliability of this new assessment named SISCUES (Similarity Index of the SCUES) in children with upper motor neuron lesions. Thirty-three patients (12.2 years [8.8;14.9]) affected by upper motor neuron lesions with mild to moderate impairments and 31 typically developing children (11.6 years [8.5;13.9]) participated. We calculated reference muscle a
SUBMITTER: Keller JW
PROVIDER: S-EPMC10454990 | biostudies-literature | 2021 Apr-Jun
REPOSITORIES: biostudies-literature