Unknown

Dataset Information

0

Association of clot ultrastructure with clot perviousness in stroke patients.


ABSTRACT: Clot perviousness on computerized tomography (CT) is predictive of response to reperfusion therapy. This study aimed to determine the association of clot perviousness with ultrastructural features of clot in stroke patients undergoing endovascular thrombectomy. We quantitatively analyzed the ultrastructural components identified using scanning electron microscopy. The clot components were determined in the inner portions of the clots. Clot perviousness was assessed as thrombus attenuation increase (TAI) using noncontrast CT and CT angiography. We compared the association between the identified ultrastructural components and clot perviousness. The proportion of pores consisted of 3.5% on scanning electron microscopy images. The proportion of porosity in the inner portion was 2.5%. Among the ultrastructural components, polyhedrocytes were most commonly observed. The mean TAI was 9.3 ± 10.0 (median 5.6, interquartile range 1.1-14.3) Hounsfield units. TAI correlated positively with inner porosity (r = 0.422, p = 0.020). Among the ultrastructural clot components, TAI was independently associated with polyhedrocytes (B = - 0.134, SE = 0.051, p = 0.008). Clot perviousness is associated with porosity and the proportion of polyhdrocytes of clots.

SUBMITTER: Kim YD 

PROVIDER: S-EPMC10477321 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Association of clot ultrastructure with clot perviousness in stroke patients.

Kim Young Dae YD   Kwon Il I   Park Youngseon Y   Lee Hyungwoo H   Lee Il Hyung IH   Lim In Hwan IH   Hong Soon-Ho SH   Lee Hye Sun HS   Nam Hyo Suk HS   Heo Ji Hoe JH  

Scientific reports 20230904 1


Clot perviousness on computerized tomography (CT) is predictive of response to reperfusion therapy. This study aimed to determine the association of clot perviousness with ultrastructural features of clot in stroke patients undergoing endovascular thrombectomy. We quantitatively analyzed the ultrastructural components identified using scanning electron microscopy. The clot components were determined in the inner portions of the clots. Clot perviousness was assessed as thrombus attenuation increa  ...[more]

Similar Datasets

| S-EPMC5137111 | biostudies-literature
| S-EPMC9462564 | biostudies-literature
| S-EPMC10432616 | biostudies-literature
| S-EPMC8564157 | biostudies-literature
| S-EPMC11303227 | biostudies-literature
| S-EPMC6394442 | biostudies-literature
| S-EPMC9131494 | biostudies-literature
| S-EPMC9376378 | biostudies-literature
| S-EPMC8208992 | biostudies-literature
| S-EPMC8324260 | biostudies-literature