Unknown

Dataset Information

0

High-throughput extraction on a dynamic solid phase for low-abundance biomarker isolation from biological samples.


ABSTRACT: Liquid biopsy, in particular circulating tumor DNA (ctDNA) analysis, has paved the way for a new noninvasive approach to cancer diagnosis, treatment selection and follow-up. As a crucial step in the analysis, the extraction of the genetic material from a complex matrix needs to meet specific requirements such as high specificity and low loss of target. Here, we developed a new generation of microfluidic fluidized beds (FBs) that enable the efficient extraction and preconcentration of specific ctDNA sequences from human serum with flow rates up to 15 µL/min. We first demonstrated that implementation of a vibration system inducing flow rate fluctuations combined with a mixture of different bead sizes significantly enhanced bead homogeneity, thereby increasing capture efficiency. Taking advantage of this new generation of high-throughput magnetic FBs, we then developed a new method to selectively capture a double-stranded (dsDNA) BRAF mutated DNA sequence in complex matrices such as patient serum. Finally, as proof of concept, ligation chain reaction (LCR) assays were performed to specifically amplify a mutated BRAF sequence, allowing the detection of concentrations as low as 6 × 104 copies/µL of the mutated DNA sequence in serum.

SUBMITTER: Alexandre L 

PROVIDER: S-EPMC10480215 | biostudies-literature | 2023

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-throughput extraction on a dynamic solid phase for low-abundance biomarker isolation from biological samples.

Alexandre Lucile L   Araya-Farias Monica M   Nguyen Manh-Louis ML   Naoumi Nikoletta N   Gropplero Giacomo G   Gizeli Electra E   Malaquin Laurent L   Descroix Stéphanie S  

Microsystems & nanoengineering 20230906


Liquid biopsy, in particular circulating tumor DNA (ctDNA) analysis, has paved the way for a new noninvasive approach to cancer diagnosis, treatment selection and follow-up. As a crucial step in the analysis, the extraction of the genetic material from a complex matrix needs to meet specific requirements such as high specificity and low loss of target. Here, we developed a new generation of microfluidic fluidized beds (FBs) that enable the efficient extraction and preconcentration of specific ct  ...[more]

Similar Datasets

| S-EPMC7397209 | biostudies-literature
| S-EPMC6278404 | biostudies-literature
| S-EPMC3991419 | biostudies-literature
| S-EPMC10483517 | biostudies-literature
| S-EPMC5589922 | biostudies-literature
| S-EPMC4821447 | biostudies-literature
| S-EPMC10676307 | biostudies-literature
2019-09-25 | PXD012851 | Pride
| S-EPMC6768029 | biostudies-literature
| S-EPMC10855760 | biostudies-literature