Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control.
Ontology highlight
ABSTRACT: Dead-time is the most important disturbance in a voltage-source inverter's operation. It introduces low-order harmonics at the inverter's output voltage. To compensate for the dead-time effects in three-phase grid-tied inverters, this paper proposes a Linear Quadratic Gaussian (LQG) multivariable control approach. The LQG multivariable control is known as a robust control approach while provides a high band-width for the closed-loop system. Therefore, it promises significant attenuations in the dead-time introduced harmonics. To achieve a high performance, we run the three-phase grid-tied inverter in the current-controlled mode. Based on the nominal multivariable model derived for the three-phase grid-tied inverter in a synchronous reference frame, the LQG controller is composed such that