Evaluation of free-floating tracheal intubation in weightlessness via ice-pick position with a direct laryngoscopy and classic approach with indirect videolaryngoscopy.


ABSTRACT: Long duration spaceflights to the Moon or Mars are at risk for emergency medical events. Managing a hypoxemic distress and performing an advanced airway procedure such as oro-tracheal intubation may be complicated under weightlessness due to ergonomic constraints. An emergency free-floating intubation would be dangerous because of high failure rates due to stabilization issues that prohibits its implementation in a space environment. Nevertheless, we hypothesized that two configurations could lead to a high first-pass success score for intubation performed by a free-floating operator. In a non-randomized, controlled, cross-over simulation study during a parabolic flight campaign, we evaluated and compared the intubation performance of free-floating trained operators, using either a conventional direct laryngoscope in an ice-pick position or an indirect laryngoscopy with a video-laryngoscope in a classic position at the head of a high-fidelity simulation manikin, in weightlessness and in normogravity. Neither of the two tested conditions reached the minimal terrestrial ILCOR recommendations (95% first-pass success) and therefore could not be recommended for general implementation under weightlessness conditions. Free-floating video laryngoscopy at the head of the manikin had a significant better success score than conventional direct laryngoscopy in an ice-pick position. Our results, combined with the preexisting literature, emphasis the difficulties of performing oro-tracheal intubation, even for experts using modern airway devices, under postural instability in weightlessness. ClinicalTrials registration number NCT05303948.

SUBMITTER: Thierry S 

PROVIDER: S-EPMC10491756 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of free-floating tracheal intubation in weightlessness via ice-pick position with a direct laryngoscopy and classic approach with indirect videolaryngoscopy.

Thierry Séamus S   Jaulin François F   Starck Clément C   Ariès Philippe P   Schmitz Jan J   Kerkhoff Steffen S   Bernard Cécile Isabelle CI   Komorowski Matthieu M   Warnecke Tobias T   Hinkelbein Jochen J  

NPJ microgravity 20230908 1


Long duration spaceflights to the Moon or Mars are at risk for emergency medical events. Managing a hypoxemic distress and performing an advanced airway procedure such as oro-tracheal intubation may be complicated under weightlessness due to ergonomic constraints. An emergency free-floating intubation would be dangerous because of high failure rates due to stabilization issues that prohibits its implementation in a space environment. Nevertheless, we hypothesized that two configurations could le  ...[more]

Similar Datasets

| S-EPMC8978307 | biostudies-literature
| S-EPMC6513507 | biostudies-literature
| S-EPMC6472630 | biostudies-literature
| S-EPMC9575044 | biostudies-literature
| S-EPMC7287461 | biostudies-literature
| S-EPMC9655434 | biostudies-literature
| S-EPMC6089856 | biostudies-literature
| S-EPMC10884075 | biostudies-literature
| S-EPMC6395053 | biostudies-literature
| S-EPMC9468586 | biostudies-literature