Unknown

Dataset Information

0

Are baseline conditions of coronary arteries sufficient for calculating angio-based index of microcirculatory resistance and fractional flow reserve?


ABSTRACT:

Background

Angio-based index of microcirculatory resistance (IMR) and fractional flow reserve (FFR) have been developed, however, the differences between baseline and hyperemic data and their effects on their computation have not yet been discussed. This study aimed to compare the diagnostic performance of a novel method for calculating IMR and FFR from coronary angiography under baseline and hyperemic conditions.

Methods

We performed a retrospective study to investigate the diagnostic performance of angiography-derived IMR (AccuIMR) and FFR (AccuFFRangio) computed from the hyperemic condition (AccuIMRhyp, AccuFFRangiohyp) and baseline condition (AccuIMRbase, AccuFFRangiobase) in 101 consecutive patients with chronic coronary syndrome (CCS) who underwent measurements of IMR and FFR at a single center, using wire-based IMR and FFR as the reference standard.

Results

AccuIMRhyp showed much better correlation with IMR than AccuIMRbase (r=0.77 vs. 0.47, P<0.001). The diagnostic accuracy and area under the curve (AUC) for identifying significant microvascular dysfunction was higher for AccuIMRhyp than AccuIMRbase [92.1% (95% CI: 85.0-96.5%) vs. 83.2% (95% CI: 74.4-89.9%), P=0.012; 0.942 (95% CI: 0.877-0.979) vs. 0.815 (95% CI: 0.726-0.886), P=0.003]. The computed AccuFFRangio showed good correlations with FFR and good diagnostic performance under both hyperemic and baseline conditions [r=0.68 vs. 0.68, P>0.99; diagnostic accuracy =95.9% (95% CI: 89.8-98.9%) vs. 94.9% (95% CI: 88.4-98.3%), P=0.728; AUC =0.989 (95% CI: 0.942-1.000) vs. 0.973 (95% CI: 0.919-0.995), P=0.381]. The net reclassification index (NRI) demonstrated that hyperemic group had improved reclassification ability compared to the baseline group in identification of IMR >25 (NRI =0.20, P<0.001) and FFR ≤0.8 (NRI =0.11, P<0.001).

Conclusions

By comparing the calculated angio-derived IMR and FFR under the baseline and hyperemic conditions, this study demonstrates that AccuIMR calculation is more accurate using the hyperemic condition, while AccuFFRangio calculation is accurate under both conditions.

SUBMITTER: Li C 

PROVIDER: S-EPMC10498260 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Are baseline conditions of coronary arteries sufficient for calculating angio-based index of microcirculatory resistance and fractional flow reserve?

Li Chenguang C   Hu Yumeng Y   Wang Jingpu J   Pan Congcong C   Lu Hao H   Wu Yizhe Y   Chen Zhangwei Z   Pei Zhiqiang Z   Shen Li L   He Jingsong J   Leng Xiaochang X   Xiang Jianping J   Ge Junbo J  

Quantitative imaging in medicine and surgery 20230809 9


<h4>Background</h4>Angio-based index of microcirculatory resistance (IMR) and fractional flow reserve (FFR) have been developed, however, the differences between baseline and hyperemic data and their effects on their computation have not yet been discussed. This study aimed to compare the diagnostic performance of a novel method for calculating IMR and FFR from coronary angiography under baseline and hyperemic conditions.<h4>Methods</h4>We performed a retrospective study to investigate the diagn  ...[more]

Similar Datasets

| S-EPMC11231276 | biostudies-literature
| S-EPMC7525716 | biostudies-literature
| S-EPMC11561489 | biostudies-literature
| S-EPMC5447668 | biostudies-literature
| S-EPMC5489582 | biostudies-literature
| S-EPMC2834756 | biostudies-literature
| S-EPMC8684425 | biostudies-literature
| S-EPMC9270302 | biostudies-literature
| S-EPMC4675752 | biostudies-literature
| S-EPMC7515763 | biostudies-literature