Robotic-OCT guided inspection and microsurgery of monolithic storage devices.


ABSTRACT: Data recovery from monolithic storage devices (MSDs) is in high demand for legal or business purposes. However, the conventional data recovery methods are destructive, complicated, and time-consuming. We develop a robotic-arm-assisted optical coherence tomography (robotic-OCT) for non-destructive inspection of MSDs, offering ~7 μm lateral resolution, ~4 μm axial resolution and an adjustable field-of-view to accommodate various MSD sizes. Using a continuous scanning strategy, robotic-OCT achieves automated volumetric imaging of a micro-SD card in ~37 seconds, significantly faster than the traditional stop-and-stare scanning that typically takes tens of minutes. We also demonstrate the robotic-OCT-guided laser ablation as a microsurgical tool for targeted area removal with precision of ±10 μm and accuracy of ~50 μm, eliminating the need to remove the entire insulating layer and operator intervention, thus greatly improving the data recovery efficiency. This work has diverse potential applications in digital forensics, failure analysis, materials testing, and quality control.

SUBMITTER: He B 

PROVIDER: S-EPMC10502073 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Robotic-OCT guided inspection and microsurgery of monolithic storage devices.

He Bin B   Zhang Yuxin Y   Zhao Lu L   Sun Zhenwen Z   Hu Xiyuan X   Kang Yanrong Y   Wang Lei L   Li Zhihui Z   Huang Wei W   Li Zhigang Z   Xing Guidong G   Hua Feng F   Wang Chengming C   Xue Ping P   Zhang Ning N  

Nature communications 20230914 1


Data recovery from monolithic storage devices (MSDs) is in high demand for legal or business purposes. However, the conventional data recovery methods are destructive, complicated, and time-consuming. We develop a robotic-arm-assisted optical coherence tomography (robotic-OCT) for non-destructive inspection of MSDs, offering ~7 μm lateral resolution, ~4 μm axial resolution and an adjustable field-of-view to accommodate various MSD sizes. Using a continuous scanning strategy, robotic-OCT achieves  ...[more]

Similar Datasets

| S-EPMC3704086 | biostudies-other
| S-EPMC3946016 | biostudies-other
| S-EPMC10403710 | biostudies-literature
| S-EPMC5425250 | biostudies-literature
| S-EPMC9593278 | biostudies-literature
| S-EPMC4108486 | biostudies-other
| S-EPMC8501038 | biostudies-literature
| S-EPMC2783284 | biostudies-literature
| S-EPMC9412682 | biostudies-literature
| S-EPMC6726124 | biostudies-literature