Ontology highlight
ABSTRACT: Background
Mechanical ventilation is a supportive therapy used to maintain respiratory function in several clinical and surgical cases but is always accompanied by lung injury risk due to improper treatment. We investigated how tidal volume and oxygen delivery would contribute independently or synergistically to ventilator-induced lung injury (VILI).Methods
Under general anesthesia and tracheal intubation, healthy female C57BL/6 N mice (9 weeks old) were randomly ventilated for 2 h by standard (7 ml/kg) or high (14 ml/kg) tidal volume at positive end-expiratory pressure (PEEP) of 2 cmH2O, with room air, 50% O2 (moderate hyperoxia), or 100% O2 (severe hyperoxia); respectively. Mice were sacrificed 4 h after mechanical ventilation, and lung ti
SUBMITTER: Xu Y
PROVIDER: S-EPMC10510264 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature