Unknown

Dataset Information

Condition optimization of eco-friendly RP-HPLC and MCR methods via Box-Behnken design and six sigma approach for detecting antibiotic residues.


ABSTRACT: A precise, Eco-friendly, and highly sensitive RP-HPLC method was employed using quality-by-design principles to concurrently identify cephalexin and cefixime residues in the manufacturing machines using a hypersil BDS C18 column (250 × 4.6 mm, 5 μm) at wavelength 254 nm. The Box-Behnken design was applied to obtain the best chromatographic conditions with the fewest possible trials. Three independent factors viz organic composition, flow rate, and pH were used to assess their effects on the responses' resolution and retention time. Overlay plot and desirability functions were implemented to predict responses of the high resolution and relatively short retention time using a mobile phase composed of acidic water: acetonitrile (85:15, v/v) at pH 4.5 adjusted by phosphoric acid with a flow ra

SUBMITTER: Y A Alanazi T 

PROVIDER: S-EPMC10514345 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature