The impact of annuloplasty ring or band implantation on post-repair mitral valve haemodynamic performance.


ABSTRACT:

Objectives

The clinical importance of optimal post-repair mitral valve diastolic performance is increasingly being recognized. The haemodynamic effect of a partial annuloplasty band implantation, in comparison to a full ring, remains insufficiently explored.

Methods

Patients undergoing mitral valve repair for pure degenerative disease between 2011 and 2019 at 2 experienced heart valve centres were eligible for inclusion. Exclusion criteria were concomitant procedures other than tricuspid valve repair and ablation procedures for atrial fibrillation. Pre-discharge and follow-up echocardiograms (1-4 years after surgery) were analysed to assess haemodynamic mitral valve performance.

Results

Of 535 patients meeting the inclusion criteria, 364 (68.0%) patients underwent full annuloplasty ring and 171 (31.0%) partial band implantation. On predischarge echocardiogram, post-repair mitral valve gradient and area did not differ between groups [2.89 mmHg (IQR 2.26-3.72) vs 2.60 mmHg (IQR 1.91-3.55), P = 0.19 and 1.98 cm2 (IQR 1.66-2.46) vs 2.03 cm2 (IQR 1.55-3.06), P = 0.15]. However, multivariable linear regression analysis demonstrated band annuloplasty as a determinant of larger valve area (coefficient 0.467 cm2, standard error 0.105, P < 0.001). On multivariable analysis, no significant impact on post-repair gradient was observed (-0.370 mmHg, standard error 0.167, P = 0.36). At follow-up, the differences between groups disappeared and multivariable regression analysis failed to demonstrate a significant impact of annuloplasty device type on mitral valve gradient (coefficient -0.095 mmHg, standard error 0.171, P = 1.00) or area (coefficient -0.085 cm2, standard error 0.120, P = 1.00). These results were confirmed with a linear mixed model analysis.

Conclusions

Partial band annuloplasty was related to an improved haemodynamic profile directly after valve repair for degenerative disease but the effect was short-lived. Our results suggest that the type of annuloplasty device has no durable impact on diastolic valve performance.

SUBMITTER: Tomsic A 

PROVIDER: S-EPMC10517645 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

The impact of annuloplasty ring or band implantation on post-repair mitral valve haemodynamic performance.

Tomšič Anton A   Sandoval Elena E   Meucci Maria C MC   Nabeta Takeru T   Castella Manuel M   Muro Anna A   Klautz Robert J M RJM   Ajmone Marsan Nina N   Pereda Daniel D   Palmen Meindert M  

European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 20230901 3


<h4>Objectives</h4>The clinical importance of optimal post-repair mitral valve diastolic performance is increasingly being recognized. The haemodynamic effect of a partial annuloplasty band implantation, in comparison to a full ring, remains insufficiently explored.<h4>Methods</h4>Patients undergoing mitral valve repair for pure degenerative disease between 2011 and 2019 at 2 experienced heart valve centres were eligible for inclusion. Exclusion criteria were concomitant procedures other than tr  ...[more]

Similar Datasets

| S-EPMC8669564 | biostudies-literature
| S-EPMC9735426 | biostudies-literature
| S-EPMC5111875 | biostudies-literature
| S-EPMC10208839 | biostudies-literature
| S-EPMC7755018 | biostudies-literature
| S-EPMC11910387 | biostudies-literature
| S-EPMC10416619 | biostudies-literature
| S-EPMC10859564 | biostudies-literature