Ontology highlight
ABSTRACT: Purpose
To report the clinical outcomes of quadriceps tendon repair using adjustable cortical fixation devices at a minimum 2-year follow-up.Methods
A retrospective chart review identified patients who underwent quadriceps tendon repair using adjustable cortical fixation devices between January 2017 and March 2020. Patients with a partial tendon rupture were excluded. Demographic and injury-specific variables were gathered preoperatively and postoperatively from the electronic medical record and patient-reported outcomes (Lysholm Knee Questionnaire, Lower Extremity Functional Scale, and SF-12) were collected via telephone at a minimum of 2 years postoperatively.Results
Fourteen quadriceps tendon repairs were included in a total of 13 patients. The average time to fo
SUBMITTER: Gould HP
PROVIDER: S-EPMC10518350 | biostudies-literature | 2023 Oct