High-Accuracy Contact Resistance Measurement Method for Liquid Metal by Considering Current-Density Distribution in Transfer Length Method Measurement.
Ontology highlight
ABSTRACT: Liquid metals (LMs) are used as stretchable conductors in various stretchable electronic devices. Moreover, such devices using Ga-based LMs have attracted considerable attention. Herein, we propose a method for accurately determining the contact resistance (Rc) between galinstan and Cu electrodes by considering the current-density distribution in transfer length method (TLM) measurement. Conventional TLM measurements assume that the sheet resistance of the metal electrode (Rshe) is negligible compared with that of the object (Rsho), such as Si. However, this assumption may be problematic because the Rsho of Ga-based liquid metals (LMs) is close to the Rshe. Therefore, we developed a method of applying
SUBMITTER: Sato T
PROVIDER: S-EPMC10521730 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA