A human papillomavirus whole genome plasmid repository: A resource for HPV DNA quality control reagents.


ABSTRACT: Well characterized reference reagents are useful for assay validation, proficiency/competency assessment, daily run controls, and to improve inter-laboratory comparisons. Synthetic human papillomavirus (HPV) DNA fragments and plasmid clones are available, but synthetic fragments include limited segments of the HPV genome and many HPV plasmids have interrupted coding regions or contain partial genomes. As a result, they are not compatible with all HPV DNA detection and typing assays. To address this need, we are establishing an HPV plasmid repository of HPV clones containing the whole genome of each type with no interruptions in coding regions. To date, HPV plasmid clones for 16 HPV types, (including all vaccine types and 14 types in clinical assays: HPV6, 11, 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and 68) have been constructed using a Gibson assembly method and validated by sequencing and the Novaplex HPV typing assay. The newly constructed HPV whole genome plasmids can serve as a quality control reagent resource for HPV DNA assays and are available for public health and research laboratories.

SUBMITTER: Thapa HR 

PROVIDER: S-EPMC10527912 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

A human papillomavirus whole genome plasmid repository: A resource for HPV DNA quality control reagents.

Thapa Hem R HR   Unger Elizabeth R ER   Querec Troy D TD  

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 20230717


Well characterized reference reagents are useful for assay validation, proficiency/competency assessment, daily run controls, and to improve inter-laboratory comparisons. Synthetic human papillomavirus (HPV) DNA fragments and plasmid clones are available, but synthetic fragments include limited segments of the HPV genome and many HPV plasmids have interrupted coding regions or contain partial genomes. As a result, they are not compatible with all HPV DNA detection and typing assays. To address t  ...[more]

Similar Datasets

| S-EPMC6367390 | biostudies-literature
| S-EPMC6952187 | biostudies-literature
| S-EPMC9338075 | biostudies-literature
| S-EPMC10925951 | biostudies-literature
| S-EPMC88645 | biostudies-literature
| S-EPMC3105373 | biostudies-literature
| S-EPMC4868726 | biostudies-literature
| S-EPMC9344924 | biostudies-literature
| S-EPMC3032008 | biostudies-literature
| S-EPMC6797070 | biostudies-literature