Parallel evaluation of alternative skin barrier models and excised human skin for dermal absorption studies in vitro.
Ontology highlight
ABSTRACT: Skin permeation is a primary consideration in the safety assessment of cosmetic ingredients, topical drugs, and human users handling veterinary medicinal products. While excised human skin (EHS) remains the 'gold standard' for in vitro permeation testing (IVPT) studies, unreliable supply and high cost motivate the search for alternative skin barrier models. In this study, a standardized dermal absorption testing protocol was developed to evaluate the suitability of alternative skin barrier models to predict skin absorption in humans. Under this protocol, side-by-side assessments of a commercially available reconstructed human epidermis (RhE) model (EpiDerm-200-X, MatTek), a synthetic barrier membrane (Strat-M, Sigma-Aldrich), and EHS were performed. The skin barrier models were mounted on
SUBMITTER: Salminen AT
PROVIDER: S-EPMC10527924 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature