Microelectrode evaluation of in situ oxidant reactivity and pH variability at new ductile iron and copper coupon surfaces.
Ontology highlight
ABSTRACT: Thirty-two short term (∼7.5 h) abiotic experiments were conducted with new ductile iron and copper coupons exposed to various water qualities, including pH (7 or 9), dissolved inorganic carbon (DIC, 10 or 50 mg C L-1) and phosphate (0 or 3 mg P L-1) concentrations and 4 mg Cl2 L-1 free chlorine or monochloramine. To quantify oxidant reactivity with the new metal coupons, microelectrodes were used to obtain oxidant (free chlorine or monochloramine and dissolved oxygen (DO)) concentration and pH microprofiles from the bulk water to near the metal coupon surface. From the microprofiles, apparent surface reaction rate constants (k) were determined for each oxidant. An ANOVA analysis evaluated if the five variables (Material, Oxidant, Phosphate, DIC,
SUBMITTER: Lee WH
PROVIDER: S-EPMC10530564 | biostudies-literature | 2023 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA