Unknown

Dataset Information

Comparison of interfragmentary compression across simulated condylar fractures repaired using four techniques.


ABSTRACT:

Introduction

Equine condylar fractures are commonly repaired using cortex screws applied in lag fashion. Inadequate interfragmentary compression can lead to post-operative complications.

Methods

Lateral condylar fractures were simulated in 21 cadaver limbs (8 third metatarsals, 13 third metacarpals). In each limb, pressure-sensitive film (Prescale®, Fuji Photo Film Co.) was placed in each osteotomy prior to repair with 4.5 mm diameter cortex screws placed in lag fashion. Screws were placed in linear (L), triangular (T), linear plus a washer (LW) and sequentially tightened triangular configurations (TD1). All screws were tightened to a torque of 4 Nm. Pressure prints obtained were scanned using dedicated software (Fuji FPD-8010E, Fuji Photo Film Co.). A Bayesian Network (BN)

SUBMITTER: Brabon A 

PROVIDER: S-EPMC10553202 | biostudies-literature | 2023

REPOSITORIES: biostudies-literature