ABSTRACT: Background
To evaluate the possible advantages of a simple spinal cord (SC) dose-limiting three-dimensional conformal radiotherapy (3D-CRT) technique in comparison to conventional two-dimensional (2D) techniques and other 3D-CRT techniques for spinal bone irradiation.Methods
For 41 spinal target volumes, seven different techniques were evaluated, using a standard schedule of 30 Gy in 10 fractions. The SC dose-limiting 3D-CRT technique 1F2S-18MV using a single posterior field (F) supplemented by two anterior segment fields (S) and 18-MV photon beams was compared to two conventional 2D techniques (a single posterior field, PA, and two opposed anterior-posterior fields, APPA), three other 3D-CRT techniques (a single posterior field supplemented by four segment fields, 1F4S; tw
SUBMITTER: Arnold CC
PROVIDER: S-EPMC10562034 | biostudies-literature | 2023 Oct