An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model.
Ontology highlight
ABSTRACT: The objective of this study was to determine compressive loads that could be generated using a tibial plateau leveling osteotomy (TPLO) jig with a tensioned strand of 18-gauge stainless steel orthopedic wire in a simulated transverse fracture model. The wire was sequentially tensioned using heavy needle holders or an AO wire tightener. Recorded loads were subsequently compared to loads generated by applying a 3.5 mm limited contact-dynamic compression plate (LC-DCP) as a compression plate. Two segments of 2 cm diameter Delrin rod were placed in a testing apparatus and used to simulate a transverse fracture. A load cell was interposed between the two segments to measure the compressive loads generated during the application of the TPLO jig or the LC-DCP. Compression was generated by sequent