Cochlear-optimized treatment planning in photon and proton radiosurgery for vestibular schwannoma patients.


ABSTRACT:

Objective

To investigate the potential to reduce the cochlear dose with robotic photon radiosurgery or intensity-modulated proton therapy planning for vestibular schwannomas.

Materials and methods

Clinically delivered photon radiosurgery treatment plans were compared to five cochlear-optimized plans: one photon and four proton plans (total of 120). A 1x12 Gy dose was prescribed. Photon plans were generated with Precision (Cyberknife, Accuray) with no PTV margin for set-up errors. Proton plans were generated using an in-house automated multi-criterial planning system with three or nine-beam arrangements, and applying 0 or 3 mm robustness for set-up errors during plan optimization and evaluation (and 3 % range robustness). The sample size was calculated based on a reduction of cochlear Dmean > 1.5 Gy(RBE) from the clinical plans, and resulted in 24 patients.

Results

Compared to the clinical photon plans, a reduction of cochlear Dmean > 1.5 Gy(RBE) could be achieved in 11/24 cochlear-optimized photon plans, 4/24 and 6/24 cochlear-optimized proton plans without set-up robustness for three and nine-beam arrangement, respectively, and in 0/24 proton plans with set-up robustness. The cochlea could best be spared in cases with a distance between tumor and cochlea. Using nine proton beams resulted in a reduced dose to most organs at risk.

Conclusion

Cochlear dose reduction is possible in vestibular schwannoma radiosurgery while maintaining tumor coverage, especially when the tumor is not adjacent to the cochlea. With current set-up robustness, proton therapy is capable of providing lower dose to organs at risk located distant to the tumor, but not for organs adjacent to it. Consequently, photon plans provided better cochlear sparing than proton plans.

SUBMITTER: Koetsier KS 

PROVIDER: S-EPMC10585330 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cochlear-optimized treatment planning in photon and proton radiosurgery for vestibular schwannoma patients.

Koetsier Kimberley S KS   Oud Michelle M   de Klerck Erik E   Hensen Erik F EF   van Vulpen Marco M   van Linge Anne A   Paul van Benthem Peter P   Slagter Cleo C   Habraken Steven J M SJM   Hoogeman Mischa S MS   Méndez Romero A A  

Clinical and translational radiation oncology 20231007


<h4>Objective</h4>To investigate the potential to reduce the cochlear dose with robotic photon radiosurgery or intensity-modulated proton therapy planning for vestibular schwannomas.<h4>Materials and methods</h4>Clinically delivered photon radiosurgery treatment plans were compared to five cochlear-optimized plans: one photon and four proton plans (total of 120). A 1x12 Gy dose was prescribed. Photon plans were generated with Precision (Cyberknife, Accuray) with no PTV margin for set-up errors.  ...[more]

Similar Datasets

| S-EPMC3874923 | biostudies-literature
| S-EPMC10783665 | biostudies-literature
| S-EPMC10870221 | biostudies-literature
| S-EPMC10271913 | biostudies-literature
| S-EPMC8563268 | biostudies-literature
| S-EPMC5425507 | biostudies-literature
| S-EPMC7137466 | biostudies-literature
| S-EPMC8655425 | biostudies-literature
| S-EPMC7961475 | biostudies-literature
| S-EPMC11341602 | biostudies-literature