3-D joint space mapping at the ankle from weight-bearing CT: reproducibility, repeatability, and challenges for standardisation.


ABSTRACT:

Objectives

We present a 3-D approach to joint space width (JSW) measurement across the ankle from weight-bearing CT (WBCT) to demonstrate inter-operator reproducibility, test-retest repeatability, and how differences in angulation affect ankle JSW distribution.

Methods

One side from repeat WBCT imaging of both feet and ankles was analysed from 23 individuals as part of their routine clinical care pathway. Joint space mapping was performed at four facets across the talus: talonavicular, talar dome and medial gutter (dome-medial), lateral gutter, and posterior subtalar. Inter-operator reproducibility was calculated for two users, while test-retest repeatability was calculated by comparing the two visits, both presented as Bland-Altman statistics. Statistical parametric mapping

SUBMITTER: Turmezei TD 

PROVIDER: S-EPMC10598168 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature