Unknown

Dataset Information

0

Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial.


ABSTRACT:

Objectives

To estimate the economic costs, health-related quality-of-life outcomes and cost-effectiveness of subthreshold micropulse laser (SML) versus standard laser (SL) for the treatment of diabetic macular oedema (DMO) with central retinal thickness (CRT) of <400µ.

Design

An economic evaluation was conducted within a pragmatic, multicentre, randomised clinical trial, DIAbetic Macular Oedema aNd Diode Subthreshold.

Setting

18 UK Hospital Eye Services.

Participants

Adults with diabetes and centre involving DMO with CRT<400µ.

Interventions

Participants (n=266) were randomised 1:1 to receive SML or SL.

Methods

The base-case used an intention-to-treat approach conducted from a UK National Health Service (NHS) and personal social services (PSS) perspective. Costs (2019-2020 prices) were collected prospectively over the 2-year follow-up period. A bivariate regression of costs and quality-adjusted life-years (QALYs), with multiple imputation of missing data, was conducted to estimate the incremental cost per QALY gained and the incremental net monetary benefit of SML in comparison to SL. Sensitivity analyses explored uncertainty and heterogeneity in cost-effectiveness estimates.

Results

One participant in the SL arm withdrew consent for data to be used; data from the remaining 265 participants were included in analyses. Mean (SE) NHS and PSS costs over 24 months were £735.09 (£111.85) in the SML arm vs £1099.70 (£195.40) in the SL arm (p=0.107). Mean (SE) QALY estimates were 1.493 (0.024) vs 1.485 (0.020), respectively (p=0.780), giving an insignificant difference of 0.008 QALYs. The probability SML is cost-effective at a threshold of £20 000 per QALY was 76%.

Conclusions

There were no statistically significant differences in EQ-5D-5L scores or costs between SML and SL. Given these findings and the fact that SML does not burn the retina, unlike SL and has equivalent efficacy to SL, it may be preferred for the treatment of people with DMO with CRT<400µ.

Trial registration numbers

ISRCTN17742985; NCT03690050.

SUBMITTER: Mistry H 

PROVIDER: S-EPMC10603454 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial.

Mistry Hema H   Maredza Mandy M   Campbell Christina C   Lois Noemi N  

BMJ open 20231018 10


<h4>Objectives</h4>To estimate the economic costs, health-related quality-of-life outcomes and cost-effectiveness of subthreshold micropulse laser (SML) versus standard laser (SL) for the treatment of diabetic macular oedema (DMO) with central retinal thickness (CRT) of <400µ.<h4>Design</h4>An economic evaluation was conducted within a pragmatic, multicentre, randomised clinical trial, DIAbetic Macular Oedema aNd Diode Subthreshold.<h4>Setting</h4>18 UK Hospital Eye Services.<h4>Participants</h4  ...[more]

Similar Datasets

| S-EPMC6373040 | biostudies-literature
| S-EPMC4366477 | biostudies-literature
| S-EPMC5574536 | biostudies-literature
| S-EPMC8322653 | biostudies-literature
| S-EPMC7608089 | biostudies-literature
| S-EPMC7794500 | biostudies-literature
| S-EPMC11323996 | biostudies-literature
| S-EPMC7712611 | biostudies-literature
| S-EPMC11355810 | biostudies-literature
| S-EPMC11458775 | biostudies-literature